CYMGRD

Design and analysis of substation grounding systems, hazard point evaluation and optimization of technically sound and cost-effective solutions.

Substation Grounding

CYMGRD, Substation Grounding

RENEWCONNECT distributes the CYMGRD software and provides technical support and training.

CYMGRD is a substation grounding system design and analysis program specially developed to help engineers optimize the design of new grounding grids and reinforce existing ones, of any shape, using built-in, easy-to-use hazard point evaluation tools.

User-friendly data entry, efficient analysis algorithms and powerful graphical features make CYMGRD a high-performance tool that helps engineers design technically sound and cost-effective solutions.

Features, Capabilities & Results Management

CYMGRD enables rapid analysis of different design solutions so that a cost-effective solution can be chosen for each installation.

The program complies with IEEE 80™ 2013, IEEE 81™ 1983 and IEEE 837™ 2002 standards.

  • Finite element analysis of grounding grid conductors and rods.
  • Calculation of the station grounding resistance (Rg) and Ground Potential Rise (GPR).
  • Touch and surface potential analysis, inside and outside the grid perimeter, with color display in 2D or 3D representation.
  • Step voltage analysis.
  • Uniform or two-layer soil model based on field measurements or user-defined values.
  • Calculation of the surface layer derating factor (Cs).
  • Library of the most common surface layer material types.
  • Library of typical substation soil resistivity values.
  • Safety assessment calculations for maximum permissible touch and step voltages according to IEEE 80™ 2000.
  • Current split factor (SF) estimated from the substation configuration data in accordance with IEEE 80™ 2000.
  • Decrement factor (DF) calculation from the bus X/R ratio and fault duration data in accordance with IEEE 80™ 2000.
  • DC component of the asymmetrical fault current taken into account in the calculations.
  • Electrode analysis for optimal sizing of conductors and rods based on the most common electrode material types, in accordance with IEEE 80-2000 and 837-2002.
  • Supports symmetrical or asymmetrical grids of any shape.
  • Arbitrarily placed ground rods.
  • Ability to model return electrodes and separate electrodes.
  • Ability to model concrete encased rods.
  • Computation of maximum single phase to ground fault current for a specified grid.

The CYMGRD / AutoCAD® Interface module allows the user to alternate between the AutoCAD® and the CYMGRD environments.

This utility is not a substitute for AutoCAD®. In fact, AutoCAD® remains a firm software requirement for CADGRD, because it is AutoCAD® that will produce the necessary *.DXF or *.DWG file(s) that contain the pictorial description of the substation grid layout realized with the CYMGRD software.

The charts functionality allows:

  • Graphical comparison of deduced soil model with field measurements, for model acceptance.
  • Color-coding of the surface potential gradients based on user-defined thresholds for touch or surface potentials. Any area of the grid can be selected with the mouse for detailed calculations and danger point evaluation.
  • Equipotential contours for surface potentials in either 2-D or 3-D plots, with facilities to examine the graphs from any desired viewing angle.
  • Graphics of touch and step voltage variation along any straight line, with comparison to the safe values computed by the safety assessment module.
  • Graphic indications on the 2-D grid layout of the area being analyzed for touch and step voltages, for easy identification of hazardous locations.