Software & Cable Thermal Analysis

CYMCAP

Ampacity and temperature rise calculation and thermal modeling of power cable installations under steady-state and transient conditions.

Power cable current-carrying capacity

Ampacity & Temperature Rise Calculation

RENEWCONNECT distributes the CYMCAP software and provides technical support and training.

CYMCAP is dedicated to the calculation of ampacity and temperature rise of power cable installations. Its accuracy provides greater confidence when upgrading existing installations and designing new ones, optimizing return on investment while promoting optimal use of installed equipment.

Features, Analyses & Additional Modules

CYMCAP is designed to perform ampacity and temperature rise calculations for power cable installations. When designing electrical installations, it is important to determine the maximum current that cables can carry without altering their electrical properties.

It covers the thermal rating of cables under steady-state and transient conditions according to the analytical techniques described by Neher-McGrath and the international standards IEC 287© and IEC 853©.

This software was jointly developed by Ontario Hydro (Hydro One), McMaster University and CYME International, under the auspices of the Canadian Electrical Association.

Validating the results obtained with CYMCAP provides greater confidence when upgrading existing power cable installations and designing new ones, thereby maximizing the benefits of the considerable investments they involve.

  • Iterative techniques based on the Neher-McGrath and IEC-60287© methods.
  • Full compliance with North American practices and compliance with IEC 60287©, IEC 60228©, IEC 60853©, etc.
  • Detailed graphical representation of virtually any type of power cable (single-core, three-core, belted, pipe-type, submarine, sheathed, and armored cables) with library enrichment.
  • Different cable installation conditions such as directly buried, thermal backfill, underground ducts or duct banks.
  • Pipe-type cables directly buried or in a thermal backfill.
  • Independent libraries and databases for cables, duct-banks, load curves, heat sources and installations.
  • Modeling of cables in air on riser poles, groups of cables in air, moisture migration, nearby heat sources and heat sinks, etc.
  • Different cable types within one installation.
  • Non-isothermal earth surface modeling.
  • Cyclic loading patterns as per IEC-60853©.
  • Multiple cables per phase with accurate modeling of the sheath mutual inductances which greatly influence circulating current losses and thus de-rates the ampacity of cables.
  • All types of sheath bonding arrangements for flat and triangular formations are supported with explicit modeling of minor section lengths, unequal cable spacing, etc.

The program supports a Transient Thermal Analysis Option which includes the following:

  • Ampacity given time and temperature
  • Temperature analysis given time and ampacity
  • Time to reach a given temperature, given the ampacity
  • Ampacity and temperature analysis as a function of time
  • User-defined load profiles per circuit
  • Multiple cables per installation
  • Circuits can be loaded simultaneously or one at a time

The CYMCAP Additional Modules offer extended capabilities to the CYMCAP software, allowing modeling more installations, particularly non-standard installations. This includes the modeling of installations with multiple ductbanks and backfills each with different thermal resistivity; the calculation of the ampacity and temperature of cables in unventilated tunnels; the rating of cables in both filled and unfilled troughs; and the rating of cables in one or more non-magnetic casings.

  • Multiple Duct Banks and Backfills
  • Advanced tunnel modeling
  • Cables in tunnels
  • Cables in Troughs
  • Multiple Casings
  • Submarine cable installations

The CYMCAP Additional Modules allow performing several analyses of interest for cables installations like evaluating the magnetic flux density at any point on or above the ground of an underground cable installation, determining the positive and zero sequence impedances and admittances for all the cables present in an installation, performing short-circuit cable ratings, determining the optimal placement of several circuits within a ductbank given specified constraints and calculating the ampacity of two circuits crossing each other.

  • Duct Bank Optimizer
  • Parametric studies
  • Soil dry-out analysis
  • Magnetic Fields
  • Cable Impedance Calculation
  • Short-Circuit Cable Rating
  • Circuits Crossing

Eaton’s CYMCAP 3D modeling module is a cutting-edge tool that enables three-dimensional thermal analysis for complex cable installations. It handles non-parallel complex cable geometries often seen in congested areas with multiple circuits crossing. It also provides valuable insights into effects produced by bending, sudden changes in cable depth and inclination, making it an indispensable asset in power cable analysis.